Skip to main content
Digital Radiography System

Raynova DRsc5

raynova drsc

RAYNOVA DRsc5

Specification

Name

Description

Technical Parameters
Portable Flat Panel Detector (1)
Detector Design

Movable Flat Panel Detector

Scintillant

GOS

Pixel Size

140 x 140µm

Pixel Matrix

3052 x 2500

Imaging Size

14 x 17 inches

A/D

16bit

Minimum Preview Image Time

3s

Rapid Physical Examination Mode

Included

Cooling Mode

Nature Cooling

Number of Flat Connetions

Support the connection of more than 2 tablets to an operating workstation via LAN

Power Supply and Transmission Mode

Power supply via cable connection and transmission of image data

Portable Flat Panel Detector (2)
Detector Design

Movable Flat Panel Detector

Scintillant

Csl

Pixel Size

139 x 139µm

Pixel Matrix

3072 x 3072

Imaging Size

17 x 17inches

A/D

16bit

Minimum Previewing Image Time

3s

Rapid Physical Examination Mode

Included

Cooling Mode

Nature Cooling

Number of Flat Connections

Support the connection of more than 2 tablets to an operating workstation via LAN

Power Supply and Transmission Mode

Power supply via cable connection and transmission of image data

Integrated Image Acquisition Workstation
Display Size

19 inches medical professional liquid crystal

CPU Main Frequency

Dual core 2.8G and above

Memory

4G

Hard Disk

500G, 7200, SATA

Network Card

Dual NIC 1000M, 100M

Operating System

Windows 7 or later updated systems

Software Function
Function

It has the functions of authority management, patient registration, image acquisition, image processing, automatic image optimization, film printing and report management.

Patient Registration

Include local registration, worklist network search, support bar code scanning.

Image Acquisition

High voltage parameters can be set in software interface.

Image Processing

Mouse right-click brightness/ contrast adjustment, LUT, ROI, annotation, marking, scale, gray bar, rotation, flip, scaling, tailoring, translation, measurement.

PACS Film Print

Mouse drag-and-drop operation, support irregular typesetting (including 3 partitions), and support the number of printers > 5

Report Management

It has the function of editing and storing the diagnostic report of picture and text, and can read and edit the report simultaneously.

Backup and Restore

With CD and DVD recording export and import image function.

DICOM Agreement

DICOM 3.0 Protocol Complying with International Standard.

Split Screen Display

Support

Multi-task Parallel Processing Function

Included

Cardiothoracic Ratio Measurement Function

Included

Long Bone Splicing Function

Included

X-Ray Generator
Maximum Output Power

50kW

Maximum Output Tube Voltage

150kV

Maximum Output Tube Current

630mA

Exposure Time Range

1 – 6300ms

APR Position Photography Procedure

1000 parts

Patient Exposure Condition Feedback Function

Included

Real Time Monitoring Function

Included

X-Ray Tube
Focal Size

Dual Focus Tube, Focal Size 0.6/1.2mm

Focus Power

50kW

Anode Target Heat Capacity

300kHU

Pipe Support Device (Column Structure)
Automatic Alignment Function

In recumbent position photography, the spherical tube and the imaging part under the bed have the function of automatic alignment.

Horizontal Motion Range of Column Along Ground Track

1300mm

Vertical Range of Motion of the Spherical Tube Along the Column

1250mm

Rotation range of Spherical tube around column

±180°

Rotation Range of Spherical Tube Around Cross Arm

±180°

Photography Flat Bed
Flat Bed Form

Fixed Type

Bed Panel Size

2000 x 740mm

Transverse Moving Distance of Bed Surface

310mm

Longitudinal Moving Distance of Bed Surface

735mm

Bed Bearing

135kg

Filter Grid

Imported fixed, non-flat integrated portable filter grids

Filter Grid Size

The sizes of filter grids are 18 x 18 inches, the ratio of grid is 8:1, and the density of grids is 40L/cm

Vertical Photographic Frame
Minimum Height of Imaging Module from Center to Ground

330mm

Vertical Motion Range of Imaging Module

1420mm

Filter Grid

Imported fixed, non-flat integrated portable filter grids

Filter Grid Size

The sizes of filter grids are 18 x 18 inches, the ratio of grids is 8:1, and the density of grids is 40L/cm

Beam Limiting Device
Revolving Around the Center Axis

±45°

Indicator Illuminance

160lux

Ruler and Laser Lamp

With ruler and laser positioning lamp

Others
Intercom System

Including built-in microphone, Hi-Fi audio

One-Button Turn-On and Turn-Off Function

Included

Automatic Prompt Function

Included

Software Authentication

The software has passed four certifications such as IHE of China Equipment Association

Configuration
Part Name

Model

FPD (1)

3543A

FPD (2)

VENU1717X

Generator (50KW)

Titan-50-R-CE

X-Ray Tube

MWHX7620A

Tube Column

KP-CY-TColumn

Patient Support

KP-CY-PSupport

Wall Bucky

KP-CY-WBucky

Collimator

KP-CY-Collimator

Imaging Workstation

KP-CYP-WS

Clinical Application Software Package

Organizational equilibrium

Automatic background recognition

Frequency domain artifact separation

Wide-angle long bone splicing

Other Components

Intercom System, Operation Manual, etc.

raynova result3
raynova result2
raynova result1